What Happened To Hemaapp, Articles S

PDF $QQH[ - mardep.gov.hk Holds the fire extinguisher securely in place but provides quick and positive release of the fire extinguisher for immediate use. Internal combustion or gas turbine propelling Carbon dioxide. hb```f`` ,@Q,-/ Z ;RPYw6$8103y@@1a n`z,bln !FVJ *W fighting equipment, as required for all ships by SOLAS Ch.II-2, Reg.15 and 16. be fitted with a steel sleeve at least 1 mm thick and at least 200 mm long divided equally on each side of the bulkhead, ceiling or lining. Previous Post Next Post However, the applicable regulations must be consulted for specific situations, especially if the SOLAS option for structural fire protection is not selected. 4 0 obj The serial number or other identifier of the fire extinguisher that was tested. Solas Regulations Of Portable Fire Extinguishers >Portable fire extinguishers should be ready to use and easily visible with recommended color cording. As per SOLAS, chapter II-2, The number of spare charges required by regulation 6.2 for portable extinguishers should be in accordance with the provisions of MSC Circular 847, namely: 100% for the first 10 extinguishers; and 50% for the remaining extinguishers, subject to a maximum of 60. 3.8.5.1 Every vessel must display "mimic" plans in accordance with regulation 13.7.2.2 and must also display those plans in every space occupied by the crew. Could be damaged because of a fire or explosion, or. Manual fire dampers must be operable from both sides of the deck or bulkhead. Every door in an "A" or "B" class division must be fitted with a thin metal identification plate that: has clearly stamped on it the door manufacturer's name, the "A" or "B" class rating, the type approval certificate number and the number of the drawing to which the door has been manufactured, and. If this is impracticable, or for other purposes, and specie rooms and storerooms. Periodic refilling of the cylinders should be in accordance with the manufacturers recommendations. not more than 20 spare charges in total, equally distributed over the available types, are required. FIR-001 5 of 24 10/21 46 CFR 118.410 - Fixed gas fire extinguishing systems. If one of those pumps is manually operated and is located outside the space where the other fire pump required by that regulation and its source of power are located, the manually operated fire pump may also be used for the emergency fire pump if one is required by regulation 10.2.2.3.1.2. PDF INTERNATIONAL MARITIME ORGANIZATION E - Gard The present booklet contains training and operational information regarding the fire. If the vessel is fitted with two or more power-driven fire pumps, a non-return valve must be fitted to the discharge line of each pump to prevent water from backing through the pump when it is not operating. To Fit on a Fire Hydrant of screw type Male Outlet.